PiloTREK FMCW - Non-contact microwave


APPLICATIONS

  • Level or volume measurement
  • Liquids, powders, granules with > 1.5
  • Medium with dust, vapour or pressurized gas layers above the product surface
  • Heavy industrial applications

FEATURES

  • 2- or 4-wire FMCW technology
  • TBF mode for low Er
  • Digital communication
  • Field indicator facility
  • High accuracy up to ± 1 mm
  • High pressure
  • High temperature range
  • Low dead band
  • Explosion-proof models

SPECIFICATIONS

  • Power supply: 24 V DC, 24 V AC, 100-120 V AC, 220-240 V AC
  • Flange temperature: -60…+250 °C
  • Pressure: 0….64 bar
  • Measuring range: up to 40 m (100m)
  • Analogue Output: 4…20 mA (active or passive)
  • Communication: HART, Profibus PA, FF, Modbus (RS485)
  • Protection: IP 66/67
  • ATEX approval:
    II 1/2 G EEx de IIC T6...T1
    II 2 G EEx de IIC T6...T1
    II 1/2 G EEx de [ia] IIC T6...T1
    II (1)2 G EEx de [ia] IIC T6...T1
    II 1/2 G EEx ia IIC T6

          


 

 

 

 

 