NIVOSONAR - Ultrasonic two-part system
APPLICATIONS
- Practically any liquid or free flowing solids
- Volume or weight calculation
- Open channel flow measurement
- Reliable measurement even under extreme conditions with vapours/fumes, stirrers, foam on chemicals or dust during pneumatic filling of powders
FEATURES
- Non-contact level metering
- Narrow 5° beam angle
- Fully temperature compensated
- Excellent signal processing via QUEST+software
- PP, PVDF, PTFE and stainless steel or foam faced transducers for solids
- Secondary lightning protection
- Explosion-proof models
SPECIFICATIONS
- Power supply:
24, 110, 230V AC or 24V DC
- Temperature:
-30 °C to 100 °C
- Pressure:
0.3 - 6 bar
- Measuring range:
0.2 to 25m liquids
0.6 to 70m solids
- Outputs:
4-20 mA, up to 8 relays, RS485
- Protection:
IP 65 or IP 68
- Approvals:
EEx ia IIB T5/T6
Class I. div.2,
Class II. div.1
Dust Ex Zone 10
|
|